Close to nine years ago, I was involved in a bid for more than 100 preconditioned air units for a low-cost U.S. airline. This airline was one of the first to completely outfit all its boarding bridges with both 400HZ and preconditioned air.
This was also just prior to the last fuel cost spike and the industries move to be “more green.” Today fuel costs are back up and green airport initiatives are much more common. The difference today is there are so many more choices and so many misunderstandings about what preconditioned air units will best service a particular operation.
I am not sure if it is the industry’s engineers or creative marketers, but there are a lot of acronyms in the preconditioned air industry:
- ACU (aircraft cooling unit).
- PCA or PC Air (preconditioned air).
- DX (direct expansion).
- AHU (air handler unit).
- CAS (central air system).
- POU (point of use).
- TMAC (trailer-mounted air conditioner).
- DAC (diesel air conditioner).
With that information we can now discuss PC Air like the pros. PC Air’s main purpose is to save aircraft operators money. Yes, it cools and heats an aircraft, but the aircraft already can do that for itself with an APU. The APU is a very expensive little engine, however.
FUEL SAVER
To understand how PC Air saves fuel we should follow an aircraft coming into a boarding bridge or ramp parking position that does not have power and air available. Either on approach or during the taxi in, the captain will turn on the APU. That way it will be ready to take over the aircraft's power loads and cooling and heating needs before the captain shuts down both main engines.
From that point until the aircraft is disembarked, catered, cleaned, boarded and engines started again, the APU would be running the entire time. For years this seemed OK until some smart people started to calculate what the costs were to do this.
The first reaction was to make sure 400HZ and 28VDC power were at either the boarding bridges or available at the ramp parking spaces. That way the power requirement of the aircraft could be transferred to an external power supply.
The problem with that was the captains still did not turn off the APUs. While air and heat are not required for aircraft operations to continue, the captains had a responsibility to make their customers comfortable and would keep the APU running just to run conditioned air into the aircraft even with external power hooked to the aircraft.
That would be like having a $1,000 electric bill to cool your house for a few hours. It is a big waste of money and energy. Besides burning a lot of fuel and making a lot of noise, many aircraft operators pay fixed maintenance costs based on cycles or run time.
After all, this also defeats the main purpose of having an APU – to provide a backup generator on board just in case of an engine generator problem and to start aircraft engines before flight.
I used to be an airline pilot for a legacy airline and one operational delay that was common would be a failed APU unit. The main reason for failure? We would be limited to a small quantity of available external air-start units to get the first engine started, which inevitably caused a delay on push back.
More importantly, if an APU is “MEL’d” (minimum equipment listed), you can still fly with that broken APU because the FAA has preapproved that failure to be acceptable for a short period of time – but there are still some very important FAA limitations in doing that. The FAA was smart enough to step in and say that a valuable backup system was not working, As a result, the agency has restricted flights with MEL’d APUs by imposing weather limitations on the pilots.
Having a MEL’d APU at the airline I flew for meant that flying in icy conditions, expected turbulence or CAT III approaches – basically very low visibility– was prohibited. This FAA requirement would often cause delays or cancellations because the weather criteria could not be met.
THE SOLUTION
PC Air units are a part of the solution to help lower these APU outages, save energy and keep the APU ready for use when it’s really needed.
By using the APU less and using external PC Air with power instead, the APU can remain off until 5 minutes before departure to be ready to start a main engine.
Look at the example where the captain turns the APU on during approach or taxi in. That APU would be running on average one hour for a narrow-body aircraft and over 1.5 hours for a wide-body aircraft. Having both power and air at the parking location would cut 90 percent of the APU usage. That means less pollution, lower maintenance costs and less MEL’d APUs, which lowers operating costs and helps on-time performance.
The low-cost airline I mentioned was one airline that figured this out early. And its solution was to put power and air in all its parking positions and standardize operations with the flight and ground crews to use these external power and air units to save significant money. While I do not have specific numbers on what it saved each year with this solution, I have seen many studies done for airports where millions of dollars can be saved annually at hub airports and hundreds of thousands of dollars at medium-sized airports with the same improvements to power and air. Most professionals in our industry do not argue these facts.
The difficulty, however, comes with different climates, different aircraft in one place and different restraints to infrastructure. Many operators do not have all the knowledge of the latest options and technologies that can help lead them in the right direction to make this investment.
Having the exact same POU DX unit at each parking spot in the entire system is not normally going to work for most operators. We can discuss some of the basic designs and the differences in technology as well as some layouts that have worked well in the past to help us better understand the options.
DX units are the most common PC Air designs used today followed by AHUs. POU DX units range typically from 20-ton to 150-tons and can be facility-powered or diesel-driven. Smaller, electric 20-ton sizes can be side-mounted on bridges and the largest 150-ton units stand-mounted. Almost anything in between is possible.
All of these DX units come now with the following refrigerant: 410A, 407C and 134A. All three are used at JBT AeroTech because each refrigerant has pros and cons depending on what you are trying to accomplish. In sizing the units for application, several factors have to be kept in mind. To name just a few:
- Ambient conditions.
- Aircraft to be serviced.
- Type of power if electric-driven.
- Desired cabin conditions.
We use an excellent calculation program that takes all of these variables and adds them up with the aircraft curves and provides recommended sizing. Even with these results, however, we still have to look harder at other factors. To name just a few:
- Type and length of delivery hose.
- The number of service doors that could be open at one time.
- How often the worst case ambient conditions will exist.
With all of this information, basic performance requirements needed to do the job can be narrowed down. Common salient characteristics are a good thing to keep in mind at this point. To name just a few:
- Tonnage.
- Airflow.
- Static pressure.
- Discharge temperature.
- Operating limitations.
- Blower horsepower.
One quick note on tonnage: Many PC Air manufacturers are starting to give names to different sizes instead of tonnage descriptions because manufacturers know best what their units are capable of cooling. Tonnages are a difficult measurement anyway because compressor tonnage and actual tonnage performance make a big difference.
In some cases, when using 134A powered by a 50HZ power supply, the compressor tonnage can be 90 tons, but the actual tonnage can be 50 tons. Derates for refrigeration and input power can be that significant with some manufacturers. This is why you really have to know what you are buying.
OTHER APPLICATIONS
Extreme Conditions: For extreme hot locations, JBT AeroTech successfully developed a DX boost unit by taking a DX unit and adding a glycol coil – like a typical AHU unit would have – to supplement the cooling capacity to achieve the desired cabin temperatures.
In the past, to cool a commercial aircraft in extreme heat was considered very improbable. Until this hybrid design between a DX and an AHU, most operators had to run the aircraft’s APU to keep the aircraft cool. This would be a typical issue for the Middle East or India, but would be overkill for Charlotte, NC, for example.
But extreme heat and humidity are two things a good designed PC Air can overcome. All DX and AHU use 100 percent outside air that is dehumidified in the process of cooling the air. If you’ve ever stood under a PC Air unit on a boarding bridge that doesn’t have the condensate hose connected, you stand a very good chance of getting soaked.
Central Systems: Central air is the other very popular option to DX POU units. The reason central systems are a good option for some is they offer a lower cost of operation and a better return on investment on projects with more than five parking positions.
A DX unit has a complete refrigeration system with compressors and extensive controls built in. A central system typically will have a greater initial capital investment than a POU, but has less overall compressor circuits, refrigeration components and has a diversity factor to help lower electrical requirements to provide as good or better cooling and heating temperatures than DX units.
A central system uses AHUs placed close to the aircraft parking positions and feeds a glycol/water mixture pumped through the AHU coils to cool or heat the air that is blown through. Compared to DX designs, AHUs are much lighter and smaller units. Since it’s an integrated system and no two central systems are exactly alike, it’s best to get design help.
While a central system may require more time and money upfront, the long-term benefits may make it a better option.
Hangar Installations: PC Air applications in hangars are starting to pick up again. Since APUs can’t be used indoors, the maintenance or loading crews typically work on aircraft in unconditioned hangers. The need to provide ventilation and cooling, however, is becoming an important enough human factor to consider these systems.
Usually a few DX units are placed outside the hanger and then ducted into the hanger underground in what is normally called a trunk line. Underground service PITs provide POU locations around the hanger. There can be more PIT positions than DX units as long as the total PC Air system has the capacity to run them. These systems can range from very basic to fully automated.
No Power: Mobile, diesel-driven PC Air units will provide the power when there's no power. The PC Air unit itself has a very common design to the all-electric DX units because the diesel generator powers the PC Air units with 60 HZ 480V power – exactly like what you would find at U.S. airports.
In fact, many of these mobile units, if placed within 100 feet of available electrical power, can be connected and operated without starting the engine.
While these units burn diesel fuel and are noise producers, it is far less noisy and fuel hungry compared to an APU. Many of these mobile units can provide the required aircraft power as well. This will help conserve ramp space and use one engine generator to power both the air and aircraft simultaneously.
In summary, PC Air is not required to cool or heat an aircraft, but it is required if you plan to take advantage of less APU usage.
Over the last nine years most operators have quantified the savings upgrading their parking positions with PC Air. Today, there are more options to consider.
These PC Air systems have a normal useful life of 10 to 15 years. Payback on investment is often less than a year. These systems can save a lot of money for operators who understand the cost differences in running power and air externally and shutting off the APUs. Knowing what will work and understanding your options will make this investment successful.
About the author: Bryan Bullerdick has worked in the industry since 1993 and is a B-737 retired pilot and instructor. Bullerdick is the sales manager for the JBT Aerotech’s new JASE division with core products in aircraft power and preconditioned air systems.